PID
The controller under every motion function, declared in include/pid.h. You can point it at your own mechanisms too.
On this page
Basic use
PID pid_arm(0.5, 0.0, 2.0); // kp, ki, kd
pid_arm.setTarget(450); // degrees
while (!pid_arm.targetArrived()) {
double output = pid_arm.update(arm.position(degrees));
arm.spin(forward, output, volt);
wait(10, msec);
}
arm.stop(hold);
update() takes the current sensor reading, computes the output, and returns it. Call it on a fixed interval. The motion code uses 10 ms.
Constructor
PID(double new_kp, double new_ki, double new_kd);
The constructor fills in defaults for the rest:
| Setting | Default |
|---|---|
small_error_tolerance |
1 |
big_error_tolerance |
3 |
small_error_duration |
100 ms |
big_error_duration |
500 ms |
integral_max |
500 |
integral_range |
0 (disabled) |
arrive |
true |
The exit condition
This is the part that makes movements settle instead of hunting.
The controller reports “arrived” through two independent checks, and either one triggers it:
| Check | Condition |
|---|---|
| Tight | error within small_error_tolerance and derivative within derivative_tolerance, held for small_error_duration |
| Loose | error within big_error_tolerance and derivative within derivative_tolerance, held for big_error_duration |
Each check has its own timer, and the timer resets as soon as the condition breaks. The robot has to hold the condition. A fast pass through tolerance fails the derivative test, so it doesn’t count.
The pairing does two jobs. The tight check catches a clean, fast settle. The loose one covers the case where the robot lands close but can’t close the last fraction of an inch, whether from friction, a dead spot, or a low kp. It exits after half a second instead of grinding against the timeout.
pid.setSmallBigErrorTolerance(0.5, 1.5); // tight, loose
pid.setSmallBigErrorDuration(50, 250); // tight ms, loose ms
pid.setDerivativeTolerance(5); // "slow enough" threshold
driveTo uses those values internally.
Disabling the exit condition
pid.setArrive(false);
targetArrived() then never returns true. Use it for a controller that runs continuously. The heading-correction PID inside the motion functions works this way, since it has no destination to reach.
Integral handling
The integral term causes the most trouble in practice, so it gets three guards.
Range gating ignores the integral while error is large:
pid.setIntegralRange(1);
Above an error of 1, sum_error stays at zero. That stops the integral winding up during a long approach and then slamming the output on arrival. Set it to 0 to disable gating.
Clamping caps the integral’s contribution:
pid.setIntegralMax(3);
Limits ki * sum_error to this value. Set to 0 to disable.
Sign reset happens automatically, with no setting. The controller zeroes sum_error whenever the error changes sign (the robot overshot) or falls within small_error_tolerance. Accumulated integral does its worst damage at both of those moments.
Start with
ki = 0. Most VEX drive movements never need integral at all, and it’s the fastest way to make a well-tuned P/D controller oscillate. Reach for it only if the robot reliably stops short of the target and stays there.
Method reference
| Method | Purpose |
|---|---|
setCoefficient(kp, ki, kd) |
Change gains on a live controller |
setTarget(target) |
Set the setpoint |
setIntegralMax(max) |
Cap the integral contribution; 0 disables |
setIntegralRange(range) |
Ignore integral outside this error band; 0 disables |
setSmallBigErrorTolerance(small, big) |
Error bands for the two exit checks |
setSmallBigErrorDuration(small, big) |
How long each band must hold, in ms |
setDerivativeTolerance(tol) |
Max rate of change still counted as settled |
setArrive(bool) |
false disables the exit condition entirely |
clearSumError() |
Zero the accumulated integral |
targetArrived() |
Has the exit condition been met? |
update(input) |
Step the controller; returns the new output |
getOutput() |
Last computed output, without stepping |
getI() |
Returns the ki coefficient |
sign(number) |
−1, 0, or 1 |
update()skips the derivative on its very first call, using the current error as the previous error. Without that, the first sample would produce a huge phantom derivative spike.
Running a subsystem on PID
The pattern below is the one commented into src/main.cpp. Add one block per mechanism.
double arm_pid_target = 0;
PID pidArm(0.5, 0.0, 2.0);
void armPID(double target) {
pidArm.setTarget(target);
pidArm.setIntegralMax(0);
pidArm.setIntegralRange(1);
pidArm.setSmallBigErrorTolerance(1, 1);
pidArm.setSmallBigErrorDuration(0, 0);
pidArm.setDerivativeTolerance(100);
pidArm.setArrive(true);
arm.spin(fwd, pidArm.update(arm.position(deg)), volt);
// or read a rotation sensor instead: arm_rotation.position(deg)
}
int armPIDLoop() {
while (true) {
armPID(arm_pid_target);
wait(10, msec);
}
return 0;
}
Start it as a task in telop() and auton():
task armTask(armPIDLoop);
Then move the mechanism by assigning the target from anywhere. The task handles the rest:
arm_pid_target = 450; // arm drives to 450° and holds there
Because the loop runs forever and re-reads
arm_pid_targetevery iteration, the mechanism actively holds position against gravity rather than just reaching it. For an arm or lift this is usually what you want. Set the target rather than commanding the motor directly, or the two will fight.